HVAC School - For Techs, By Techs

Troubleshooting Tips and Tricks w/ Let's Be Techs

·43 min·4 clips
Johnny Hall shares how a contractor's legal trouble accidentally launched his HVAC career.
The HVAC School Podcast starts with banter about Testo 605i, delivered capacity, and a dream involving Jim Berger. Brian Orr then introduces Johnny Hall, who has been around the social media and YouTube scene on and off. The conversation turns to blown fuses and the practical steps behind finding the fault. Hall and Orr discuss isolating the circuit causing the problem before leaning on short-finder tools. A contactor comes up as one of the isolation tricks, and Orr notes that it was an idea he had not thought of before. The discussion moves to transformer failure without a blown fuse. Orr works through the arithmetic for a 40 VA residential HVAC transformer by dividing 40 by 24, arriving at a 1.66-amp rating. The speakers separate an operational overcurrent from a short protected by a five-amp fuse. UV lights and other added equipment come in as examples of loads that can push a transformer too far. Multi-stage compressors and extra controls fit into that same troubleshooting picture. Float switches get their own warning. The speakers describe micro switches fusing closed when too much current passes through them, then connect that failure to aftermarket equipment such as damper panels, UV lights, and 24-volt IAQ products. The conversation also notes that multiple zones may be powered from one unit transformer instead of a separate transformer. Repeated transformer trouble leads into primary and secondary failure. The speakers leave room for exceptions while urging technicians to pay attention when the same problem shows up more than once. Near the close, the show mentions the HVACR School Symposium returning to Ocoee, Florida, and points listeners toward the website for updates. A Mississippi hippie joke arrives before the regular sign-off and request for a review.

As heard by us

A grounded 24-volt HVAC troubleshooting discussion focused on isolation, added loads, and repeat transformer trouble.

The episode turns a blown low-voltage fuse into a real troubleshooting process, not a quick label for every 24-volt problem. Brian Orr and Johnny Hall keep the focus on isolation: find the circuit that is taking out the fuse, then look closely at added controls and loads before…

Read the full review in PlayNext →

Why you'd press play

Need to stop blaming the five-amp fuse for every 24-volt problem?

Read the full recommendation in PlayNext →
Listen to the show on